Signal converters are signal conditioners plus a
processing unit to further simplify operations. Ultrasonic Signal
Converters are composed of a processing unit, driver and an amplifier.
The driver boosts power to fully excite the sensor. The returning echo
is filtered, clamped, amplified and made available on an output wire.
The illustration below shows the basic building blocks
of the Hexamite Ultrasonic Signal Converters. Input is fed through a
capacitor and clamped before it is conditioned for amplification.
Amplification is typically about 1000 and the signal is made available
at the output through a capacitor. The device has a processing unit, to
further simplify applications
Electrical Specification |
Color |
Function |
Parameter (Volt) |
Red |
Supply |
0 < Vsupply < 16 |
Orange |
Analog Out |
0 < V(p-p) < 16s |
Yellow |
Pulse In |
Low: V < 2.5 / High:
V > 0.8 |
Green |
Return (GND) |
0 |
Brown |
Comparator Out |
0 < Vcomp <= 5 |
Purple |
Analog Level Out |
0 < V <= 5 |
Blue |
Pulse Control |
Low: V < 2.5 /
High: V > 0.8 |
Tx Wire (shielded) |
Sensor Actuation (drive) |
V(p-p) ~ 6 * Vsupply |
Rx Wire (shielded) |
Sensor Monitor |
Signal input (micro volts) |
The following illustration shows how the Hexamite signal
conditioner can be utilized. A pulse of amplitude greater than 2.5 volts
can be applied to the blue wire. The processor will for the duration of
the pulse, transmit a train of pulses at a frequency specified for the
signal converter.
Alternatively the blue wire can be grounded or connected
to the green wire, in this case the user can send a specific form of
pulse train through the yellow wire. Typically 20 to 40 pulses are
required to excite the sensor fully. After the pulse train has entered
the Power Boost Driver, it may be necessary to wait a few milliseconds
for the result from the pulse train to be echoed back to the sensor. The
sound travels approx. 344m/s hence if the surface creating the echo is
10 m away, it will take the signal about 60 mS to travel to the surface
and back. Therefore train pulse repetition should not exceed 16 times
per second.
Below the RX and the TX lines are connected together,
here the transducer is a single transceiver. The excitation is about a
million times more powerful than the echo that needs to be detected. It
can take some time for the sensor to settle after excitation, typically
a few milliseconds.
WARNING if the device is reverse polarized or if
the Absolute Maximum Ratings are violated, device can be damaged.
ABSOLUTE MAXIMUM RATINGS |
Ambient temperature during operation |
-40°C to +125°C |
Storage temperature |
-65°C to +150°C |
Voltage on the Red wire
with respect to the green wire |
-0.2 < V <17V |
Current in or out of all
wires except Red or Green |
< | 20mA | |
|